For hazardous workshops that need an explosion-proof electric-hoist crane while also controlling headroom, crane self-weight and building loads.

Henan Mine Crane lhb explosion-proof hoist crane showing the crane structure and lifting arrangement.
The LHB explosion-proof electric-hoist overhead crane uses an explosion-proof electric hoist as its lifting mechanism and is intended for intermittent, repetitive material and equipment handling in explosive environments. It provides vertical lifting, cross travel and long travel.
For a buyer, the explosion-protection specification must be defined before final crane selection. The source confirms suitability for gas and dust explosion-proof environments, but it does not publish one universal protection grade. Capacity, span, lifting height, headroom and hazardous-area data should therefore be reviewed together.
| Product Model | LHB |
| Type-Test Product Name | Explosion-Proof Bridge Crane |
| Lifting Mechanism | Explosion-proof electric hoist mounted on a trolley frame |
| Lifting Capacity | Configured according to project requirements |
| Span | Configured according to runway center distance |
| Lifting Height | Configured according to workshop / process requirements |
| Working Duty | Selected from load spectrum and operating frequency |
| Explosion Protection | Configured according to the approved hazardous-area specification |
| Control Method | Configured according to project requirements |
Request A LHB Explosion-Proof Hoist Crane Quote
Explosion-proof electric hoist is used as the lifting mechanism.
Designed for material and equipment handling in explosive environments.
Provides vertical lifting, cross travel and long travel.
For a new purchase, any capacity, span, speed, duty, clean-class or explosion-protection value that is not published on the source page should be confirmed from the actual project rather than copied from a similar crane model.
The product is specifically built around an explosion-proof hoist rather than a general-purpose lifting mechanism.
The seated hoist arrangement improves usable hook height where roof clearance is limited.
A lighter crane can reduce dead load on runway beams and building columns.
Lower wheel loads can be valuable in light industrial buildings or retrofit projects.
The source confirms suitability for gas and dust explosion-proof requirements, with the final grade selected from the project classification.
Additional source product view of the LHB Explosion-Proof Hoist Crane and its explosion-protected lifting arrangement. |
Additional source product view of the LHB Explosion-Proof Hoist Crane and its explosion-protected lifting arrangement. |
| Bridge Structure | Overhead bridge selected from capacity, span and runway conditions. |
| Explosion-Proof Electric Hoist | Primary lifting mechanism for the classified environment. |
| Low-Headroom Trolley Frame | Supports the seated hoist and improves vertical hook space. |
| Bridge / Trolley Travel System | Provides longitudinal and transverse movement. |
| Explosion-Protected Electrical System | Specified according to the approved hazardous-area classification and governing standard. |
| Model | LHB |
| Product Type | LHB Explosion-Proof Electric Hoist Overhead Crane |
| Type-Test Product Name | Explosion-Proof Bridge Crane |
| Lifting Mechanism | Explosion-proof electric hoist mounted on a trolley frame |
| Capacity | Project-specific |
| Span | Project-specific |
| Lifting Height | Project-specific |
| Hoisting / Travel Speed | Project-specific unless explicitly stated by the source |
| Working Duty | Project-specific |
| Control Method | Project-specific; source-confirmed options are listed where applicable |
| Explosion-Protection Grade | Project-specific; must match the buyer's approved hazardous-area classification |
| Power Supply | According to site electrical conditions |
| Installation / Building Interface | According to workshop, runway and crane configuration |
Source-confirmed product facts:
Buyer-defined items for quotation:
| Gas Hazard Areas | Industrial workshops where flammable gas or vapor requires explosion-protected lifting equipment. |
| Combustible Dust Areas | Material handling where dust explosion protection is required. |
| Chemical / Process Workshops | General maintenance and production lifting under classified conditions. |
| Light Industrial Hazardous Bays | Projects where both explosion protection and lower building loads are important. |
Provide the approved zone/division or other project classification, hazardous medium and governing standard.
State whether the risk is gas/vapor, combustible dust or both, together with group and temperature data where required.
Provide runway and roof elevations so the low-headroom trolley arrangement can be evaluated.
Provide the maximum suspended load, runway center distance and actual hook-height requirement.
For light or existing buildings, provide runway-beam and column information so wheel loads can be reviewed.
Before manufacture and installation, confirm runway span, rail or runway-beam condition, elevation, straightness, available headroom, electrical supply and erection access. The hazardous-area boundary and equipment classification should also be confirmed before final electrical selection.
Maintenance should follow the final supplied crane manual and the plant's hazardous-area procedures. Routine inspection should cover hoisting mechanisms, brakes, ropes, hooks or attachments, wheels, drives, fasteners, limits, seals and explosion-protected electrical components. Clean explosion-proof cranes also require cleaning and inspection procedures that preserve contamination-control performance.
| 1 | Approved hazardous-area classification |
| 2 | Hazardous medium: gas / vapor / dust |
| 3 | Gas or dust group and temperature class if applicable |
| 4 | Maximum lifted load including rigging |
| 5 | Span |
| 6 | Lifting height |
| 7 | Available headroom |
| 8 | Runway length |
| 9 | Workshop / runway drawing |
| 10 | Operating frequency and duty |
| 11 | Control method |
| 12 | Power supply / governing standard / destination |
The source page does not publish one fixed universal grade. The final protection level must be selected from the buyer's approved hazardous-area specification.
Yes. The source explicitly states that dust explosion-proof environments can be addressed.
The source highlights low headroom, low self-weight and low wheel pressure.
Send hazardous-area data together with capacity, span, lifting height, headroom, runway length and workshop drawings.
Send your hazardous-area classification together with lifting capacity, span, lifting height, runway length, workshop drawing, operating cycle and control requirements. Henan Mine Crane engineers will review both the lifting duty and the explosion-protection requirements before preparing a project-specific configuration and quotation.